Murfreesboro, TN Zoning

16 districts. 5 overlays.
This profile is an earlier edition — some fields may be incomplete. An updated profile is in progress.

Overview

Worth knowing
  • City Core Overlay (CCO) covers 920 acres of downtown; established 2019 with significant density/height bonuses for mixed-use projects
  • Gateway Design Overlay (GDO-1, GDO-2) established 2019-2020 for I-24 and US-41 corridors; requires architectural compatibility
  • RS-A Type 2 and Type 3 permit zero-lot-line development; Type 3 new 2025 addition with higher density (14.5 du/ac) and height (45 ft)

+ 6 more in Quirks & notes

Districts

res_sf 3com 3ind 3spec 3res_th 2mu 2
CodeNameCategory Min lotHeight CoverageFAR Du/acParking Setbacks F/S/R
RS-15Residential Single Family — 15,000 sfres_sf15,000 sf35 ft0.252.9225 / 10 / 20
RS-10Residential Single Family — 10,000 sfres_sf10,000 sf35 ft0.34.4225 / 8 / 20
RS-6Residential Single Family — 6,000 sfres_sf6,000 sf35 ft0.357.3220 / 6 / 20
RS-A Type 2Residential Single Family — Attached Type 2res_th4,000 sf35 ft0.410.91.515 / 0 / 15
RS-A Type 3Residential Single Family — Attached Type 3res_th3,000 sf45 ft0.451.214.51.2515 / 0 / 15
CFCommercial — Flex Usecom45 ft0.61.510 / /
CHCommercial — Highwaycom55 ft0.71.820 / /
CLCommercial — Localcom35 ft0.51.25 / /
MUMixed-Use Districtmu65 ft0.752.5250 / /
HDMUHistoric Downtown Mixed-Usemu75 ft0.83300 / /
L-ILight Industrialind10,000 sf55 ft20 / 10 / 10
G-IGeneral Industrialind20,000 sf75 ft25 / 15 / 15
H-IHeavy Industrialind50,000 sf85 ft30 / 20 / 20
PRDPlanned Residential Developmentspec / /
PUDPlanned Unit Developmentspec / /
PCDPlanned Commercial Developmentspec / /

Confidence: confirmed partial under review not found

Overlays

H-1
Historic District Overlay — H-1
HP
§64-4-101 et seq.

Mapped historic districts within City of Murfreesboro; downtown core and designated historic neighborhoods

design_reviewRequired for exterior alterations, new construction, demolition
architectural_guidelinesApplied per district character standards
certificate_of_appropriatenessRequired before permitting
demolition_reviewRequires historic preservation review
CCO
City Core Overlay — CCO
DT
§64-4-201 et seq.

920-acre downtown core area established 2019; concentrated in downtown mixed-use district

permitted_usesMixed-use (residential, retail, office, hospitality)
density_bonusAllows increased density/height for projects meeting design/public benefit criteria
parkingReduced parking requirements; encourages public parking
streetscape_standardsPedestrian-oriented design; street-level retail required
mixed_use_requirementVertical or horizontal mixing encouraged
GDO-1, GDO-2
Gateway Design Overlay — GDO-1 and GDO-2
COR
§64-4-301 et seq.

Primary entrances to city (I-24 corridors, US-41 segments); established 2019-2020

design_standardsArchitectural compatibility with gateway identity
signage_standardsMonument signs, reduced pole signs; visual quality emphasis
setback_modificationMay require greater setbacks for visual prominence
landscapingEnhanced landscaping and screening required
height_considerationGateway structures may be taller if design-appropriate
FP
Floodplain Management Overlay
FP
§64-4-401 et seq.

All lands within FEMA-mapped 100-year flood zone; includes Stones River floodplain and tributary floodways

elevation_freeboard_ft1[1]
fill_restrictionNo fill permitted in floodway without compensatory storage
use_restrictionProhibits certain uses in floodway; residential allowed with elevation
manufactured_homesRestricted or prohibited in flood zone
substantial_improvement_threshold0.5[2]
CU
College/University Overlay — MTSU Context
INS
§64-4-501 et seq.

Middle Tennessee State University campus areas and surrounding compatibility zones; campus-adjacent development coordination

density_considerationMay accommodate higher residential density to support student housing
use_restrictionsCertain commercial uses restricted; student-oriented uses encouraged
parkingReduced parking in proximity to MTSU shuttle/transit
noise_considerationMay have quiet hours or noise restrictions

Adopted building codes

Major cities adopt newer locally

2012
2021
2017
2012
IECC (Residential)
2009
IECC (Commercial)
2012

Click a code label to open its state-by-state adoption atlas.

Quirks & notes

  • City Core Overlay (CCO) covers 920 acres of downtown; established 2019 with significant density/height bonuses for mixed-use projects
  • Gateway Design Overlay (GDO-1, GDO-2) established 2019-2020 for I-24 and US-41 corridors; requires architectural compatibility
  • RS-A Type 2 and Type 3 permit zero-lot-line development; Type 3 new 2025 addition with higher density (14.5 du/ac) and height (45 ft)
  • HDMU (Historic Downtown Mixed-Use) permits 75 ft height and 30 du/ac in downtown core; highest density in residential code
  • Murfreesboro is Nashville metro area city with strong university presence (MTSU); College/University overlay coordinates campus-adjacent development
  • City Core Overlay reduces parking requirements and encourages public parking; incentivizes walkability in downtown
  • Historic District overlay (H-1) predates recent overlays; integrates with City Core and Gateway overlays for layered regulation
  • FEMA floodplain management significant regulatory constraint due to Stones River and tributary floodways throughout city
  • Floodplain overlay parameters inferred from TN state minimum standards; site-specific BFE values require FEMA map review

Formulas

Definitions

height
Measured from grade to peak/roof deck per §64-3-1 et seq.
lot_coverage
Percentage of lot area occupied by building footprint; includes all structures
du_ac
Dwelling units per acre of developable land
far
Floor area ratio stated for multi-family and commercial
parking
Spaces per dwelling unit or per 1,000 sf GFA where applicable
setback
Minimum distances from property line to building wall

Massing explorer

Interactive 3D comparison across every district. Drag to orbit, scroll to zoom, use the slider to walk districts, and toggle applicable overlays in the right-side panel.

Sort by
LOW
HIGH
drag to orbit · scroll to zoom
Max height
ft
Floor area ratio
Lot coverage
%
Setbacks (F / S / R)
ft
Parking
/unit
Max density
du/ac
Min lot size
sf
Copy zoning profile
Loading…
District Category Height FAR Coverage Setbacks Parking Density Min lot Overlays

Sources & references

Citations
  1. [1] i
  2. [2] i

Research status

Data quality

78%completeness35 confirmed12 partial18 inferred
Documented gaps
  • College/University overlay (MTSU context) parameters require direct ordinance section review
  • Specific FAR values for RS-A Type 2 inferred from lot coverage and typical TN townhouse standards
  • Floodplain overlay BFE values and floodway determinations require FEMA map and city-maintained overlay map
  • City Core Overlay density bonus mechanics and public benefit criteria require detailed ordinance section review

Known issues

schema:v1-legacypriority:lowdata:gaps-present

Other cities in this state

Nearest-alphabetical profiles. Click through to compare zoning patterns side-by-side.