Brownsville, TX Zoning

10 districts. 7 overlays. 5 applicable state preemptions.

Overview

Worth knowing
  • SB 840 mandatory MF-by-right APPLIES (Brownsville 187k ≥ 150k + Cameron 423k ≥ 300k). All C-1, C-2, C-3, MU, and I-1 (warehouse) zones now host MF-by-right at ≥36 du/ac, ≥45 ft height (or city's highest, whichever greater), ≤25 ft setbacks, ≤1 parking space per unit. Historic downtown overlay may conflict with SB 840 floors; SB 840 does not carve out historic districts.
  • SB 15 (2025) + Colonia Integration: Cameron County has ~500 active colonias with ~30-50 overlapping Brownsville corporate limits + 5-mile ETJ. SB 15 enables sub-4,000 sf lots once Article 3 platting and water/sewer formalization complete. 5-15 year phased infrastructure buildout.
  • v1 profile erroneously cited zoning as 'Chapter 23'; v2 corrects to Chapter 348 (Zoning) plus Part II Article 4 (Zoning Regulations) on Municode. Chapter 308 is the parallel Flood Damage Prevention chapter.

+ 6 more in Quirks & notes

Districts

res_sf 3com 3ind 2res_mf 1mu 1
CodeNameCategory Min lotHeight CoverageFAR Du/acParking Setbacks F/S/R
R-1Single-Family Residential (Low-Density)res_sf7,500 sf35 ft0.4125 / 7 / 20
R-2Single-Family Residential (Medium-Density)res_sf5,000 sf35 ft0.5220 / 5 / 15
R-3Multifamily Residentialres_mf87,120 sf50 ft0.636[1]1[2]25 / 10 / 25
R-MHMobile Home Communityres_sf87,120 sf15 ft0.350 / 25 / 25
C-1Neighborhood Commercialcom5,000 sf45 ft0.8010 / 0 / 10
C-2General Commercialcom43,560 sf65 ft0.85015 / 5 / 15
C-3Heavy Commercial / Auto-Orientedcom87,120 sf50 ft0.6025 / 5 / 25
MUMixed-Usemu21,780 sf75 ft0.91[3]5 / 0 / 15
I-1Light Industrialind87,120 sf45 ft0.625 / 10 / 25
I-2Heavy Industrialind217,800 sf65 ft0.550 / 25 / 50

Confidence: confirmed partial under review not found

Overlays

FP
Floodplain and Hazard Overlay
FP
Chapter 308 (Flood Damage Prevention) + Chapter 348 (Zoning) · §308 FLDAPR; §348 cross-reference
base_flood_elevationFEMA-mapped; Rio Grande reach ~30-40 ft NAVD88
freeboard_ft1-2 ft above BFE (typical Valley city standard)
fill_no_rise_certification_requiredTrue
floodway_encroachment_max_wse_increase_pct1.0
resaca_setback_ft50-75
basement_prohibitedTrue
utilities_elevation_or_floodproofing_requiredTrue
surge_zone_appliesTrue
H
Historic Preservation Overlay
HP
Chapter 348 Zoning (Historic District Article) · §348 CH ZO (Historic District sub-article)
demolition_review_requiredHPC approval; cannot be arbitrary
facade_alteration_reviewMaterial, fenestration, color, signage
new_construction_design_compatibilityHeight, massing, setback consistent with historic context
addition_standardsSubordinate scale; differentiation from original
sign_regulationsSize, material, placement compatibility
parking_variance_for_historic_lotsReduced/off-site parking permitted
PORT
Port of Brownsville Industrial Overlay
SPD
Chapter 348 Zoning; Port of Brownsville Master Plan; Brownsville Navigation District · §348 CH ZO (Industrial/Port districts)
heavy_industrial_uses_by_rightTrue
hazardous_materials_storage_allowedPetroleum, chemicals, ag products, bulk material
noise_standard_dBA_property_line75-85
setback_from_residential_ft100-500
residential_uses_prohibited_or_bufferedTrue
hours_of_operation24/7 cargo operations
port_authority_jurisdiction_concurrentTrue
SPACEX
SpaceX Boca Chica Launch Facility Buffer
AP
Chapter 348 Zoning; FAA 14 CFR Part 420/450 incorporation by reference; Cameron County coordination · §348 CH ZO + 14 CFR Part 420 (federal)
faa_launch_corridor_azimuth_restrictionLateral/altitude separation per active FAA license
noise_impact_zone_dBA_peak_launch80-120
debris_trajectory_radius_mi2-5
residential_use_restricted_within_debris_zoneTrue
height_restriction_faa_ols_above_ft35-50
obstruction_lighting_red_requiredTrue
evacuation_route_preservationTrue
AIR
Brownsville South Padre Island International Airport (BRO) Airspace Overlay
AP
Chapter 348 Zoning; FAA 14 CFR Part 77 · §348 CH ZO (Airport Hazard / Part 77)
part_77_surfaces_adoptedTrue
max_height_in_approach_cone_ft_aglVariable by distance/slope (20:1 or 50:1 slope)
rpz_incompatible_uses_prohibitedResidential, schools, hospitals, places of public assembly
dnl_65_residential_discouragedTrue
dnl_70_residential_prohibitedTrue
obstruction_lighting_required_above_heightTrue
faa_form_7460_1_requiredNotice of proposed construction for objects penetrating Part 77 surfaces
COL
Colonia Integration / Subdivision Platting Overlay
SPD
Part II Article 3 (Subdivision Regulations); Texas Local Gov't Code Ch. 232; Texas Water Code §16.343; HB 1001 / Model Subdivision Rules · Art. 3 SURE; TX LGC §232.023-§232.0305
platting_mandateAll subdivisions must be formally platted to receive city water/sewer service per TX Water Code §16.343 and TX LGC §232
road_improvement_standardsDedicated ROW, pavement, drainage per Article 3
water_sewer_extension_required_condition_of_platTrue
sb15_small_lot_override_allowedLots ≤4,000 sf permitted per SB 15 (2025) with infrastructure formalized
easement_formalization_requiredTrue
phase_in_timeline_years5-15
etj_jurisdiction5 miles beyond city limits per TX LGC §42.021 (Brownsville population-tier ETJ radius)
BORDER
Rio Grande Border / International Boundary Overlay
SPD
Chapter 348 Zoning; coordination with federal CBP / GSA / USIBWC; riparian easements · §348 CH ZO (coordination provisions) + 22 USC §277 IBWC
cbp_operational_zone_no_buildWithin sight/approach of POE facility
riparian_setback_from_rio_grandeVariable; coordinated with USIBWC levee maintenance easement
international_bridge_approach_clearanceNo development obstructing bridge sight lines or queueing lanes
airspace_class_b_c_restrictionsLow-altitude federal restrictions near border corridor and BRO
wildlife_corridor_coordinationUSFWS Lower Rio Grande Valley National Wildlife Refuge adjacency; Sabal Palm Sanctuary

State preemptions

TX SB 840applies
Qualifying condition
City pop 187,063 ≥ 150,000 AND Cameron County pop 423,163 ≥ 300,000
Effect
Multifamily-by-right in commercial, office, retail, warehouse, and mixed-use zones (C-1, C-2, C-3, MU, I-1) at ≥36 du/ac, ≥45 ft height, ≤25 ft setbacks, ≤1 parking space per unit.
TX SB 15applies
Qualifying condition
Lot-size threshold (≤4,000 sf) applies to all qualifying lots statewide without population precondition.
Effect
Limits city regulation of setbacks, parking, height, and bulk on lots ≤4,000 sf. Enables 'missing middle' on small urban lots and unlocks colonia small-lot platting once infrastructure formalized.
TX SB 2038applies
Qualifying condition
Brownsville has a 5-mile ETJ per TX LGC §42.021 (pop 100,000+ tier); SB 2038 applies statewide to cities with ETJ.
Effect
Property owners may petition for release from ETJ; limits city's ability to retain ETJ jurisdiction for colonia-platting and ordinance enforcement.
TX HB 2127 (Texas Regulatory Consistency Act / 'Death Star' bill)applies
Qualifying condition
Statewide; applies to all Texas home-rule cities.
Effect
Preempts local regulations in agriculture, business/commerce, finance, insurance, labor, natural resources, occupations, and property domains where state law occupies the field. Limits reach of municipal business-operations ordinances adjacent to zoning (e.g., predatory-lending, contractor registration).
TX STR Preemption (HB 3903 / pending case law)applies
Qualifying condition
Statewide STR preemption framework evolving; Brownsville does not currently have aggressive STR regulation, so practical preemption impact is low. Monitored for legislative updates.
Effect
Limits city ability to ban or materially restrict short-term rentals in residential zones.

Adopted building codes

Home rule; major cities on 2024 IBC

2018
2021
2023
Local adoption
IECC (Residential)
2015
IECC (Commercial)
2015

Click a code label to open its state-by-state adoption atlas.

Quirks & notes

  • SB 840 mandatory MF-by-right APPLIES (Brownsville 187k ≥ 150k + Cameron 423k ≥ 300k). All C-1, C-2, C-3, MU, and I-1 (warehouse) zones now host MF-by-right at ≥36 du/ac, ≥45 ft height (or city's highest, whichever greater), ≤25 ft setbacks, ≤1 parking space per unit. Historic downtown overlay may conflict with SB 840 floors; SB 840 does not carve out historic districts.
  • SB 15 (2025) + Colonia Integration: Cameron County has ~500 active colonias with ~30-50 overlapping Brownsville corporate limits + 5-mile ETJ. SB 15 enables sub-4,000 sf lots once Article 3 platting and water/sewer formalization complete. 5-15 year phased infrastructure buildout.
  • v1 profile erroneously cited zoning as 'Chapter 23'; v2 corrects to Chapter 348 (Zoning) plus Part II Article 4 (Zoning Regulations) on Municode. Chapter 308 is the parallel Flood Damage Prevention chapter.
  • SpaceX Boca Chica / Starbase: ~22 mi SE of downtown; FAA 14 CFR Part 420/450 launch-license corridor overlies south/southeast Brownsville along SH 4. Federal preemption dominates on launch-day evacuation, debris zones (2-5 mi radius), and OLS. SB 840 floors must yield to FAA/Part 420 envelopes. Unique among all US qualifying SB 840 cities.
  • Brownsville South Padre Island International Airport (BRO): Part 77 surfaces constrain height east of SH 48; RPZ prohibits residential/school/hospital/assembly uses; DNL 65/70 contours attenuate SB 840 MF-by-right near airport.
  • Rio Grande resaca hydrology: oxbow-lake drainage unlike typical TX cities. Floodplain overlay spans riverine (Rio Grande 100/500-yr), resaca backwater (50-75 ft setbacks typical), AND Gulf storm-surge A/V-zones (18 mi inland). Reduces developable area across significant fraction of city.
  • Port of Brownsville: Brownsville Navigation District has concurrent proprietary jurisdiction over port-owned land. Heavy-industrial corridor along SH 48/Brazos Island Channel; residential incompatible or buffered 100-500 ft. Port Master Plan parallel to Ch. 348 zoning.
  • Rio Grande border / CBP / USIBWC: Four international bridges with federal POE operational zones; USIBWC levee maintenance easements along Rio Grande; USFWS Lower Rio Grande Valley NWR and Sabal Palm Sanctuary adjacency. Federal layers supersede zoning within coordinated corridors; downtown riverfront density materially constrained.
  • Hurricane/tropical storm exposure: 18 mi inland from Gulf of Mexico; Gulf storm surge, wind, and rainfall during Atlantic hurricane season. IBC/IEBC wind-load and foundation anchoring standards typical; insurance/flood-insurance costs higher than inland TX.

Formulas

Definitions

height
Grade to highest point of structure
lot_coverage
Building footprint / lot area
far
Gross floor area / lot area
du_ac
Dwelling units per acre
setback_front
Front property line to nearest building face
setback_side
Side property line to nearest building face
setback_rear
Rear property line to nearest building face
parking
Spaces per dwelling unit unless noted

Capacity calculations

max_footprint_sf
lot_area_sf * lot_coverage
max_gfa_sf
lot_area_sf * far
max_units_from_density
lot_area_sf * du_ac / 43560
parking_required
units * parking

Massing explorer

Interactive 3D comparison across every district. Drag to orbit, scroll to zoom, use the slider to walk districts, and toggle applicable overlays in the right-side panel.

Sort by
LOW
HIGH
drag to orbit · scroll to zoom
Max height
ft
Floor area ratio
Lot coverage
%
Setbacks (F / S / R)
ft
Parking
/unit
Max density
du/ac
Min lot size
sf
Copy zoning profile
Loading…
District Category Height FAR Coverage Setbacks Parking Density Min lot Overlays

Sources & references

Primary source
municode · CH 348 / Part II Art. 4 · Municode current supplement · retrieved 2026-04-18

Municode SPA: shell HTML renders via scripted fetch but section-level text requires browser/JS. Chapter 348 is the primary Zoning chapter; Article 4 (Zoning Regulations) of Part II Code of Ordinances contains overlapping zoning procedures (procedure/PLDEDI = planned developments). v1 incorrectly labeled zoning as Chapter 23; corrected to Chapter 348 in v2. Article 3 is Subdivision Regulations (colonia-adjacent). Live section-text extraction deferred to freshness-auditor due to Municode SPA.

Citations
  1. [1] reempted_by_state
  2. [2] reempted_by_state
  3. [3] reempted_by_state

Research status

Publication gates

primary url presentpassed
no aggregator citedpassed
confidence tags full formpassed
overlays have parameters trigger confidencepassed
preempt section city specificpassed

Data quality

72%completeness10 confirmed42 partial28 inferred
Documented gaps
  • Section-level dimensional KPI retrieval from Ch. 348 Article III (Districts in General) for each base district
  • Historic Preservation Overlay design review criteria and HPC approval process (section-level)
  • Airport Hazard Overlay Part 77 surface slopes and RPZ boundaries as codified in Ch. 348
  • SpaceX/FAA overlay codification vs. incorporation by reference
  • Port of Brownsville municipal-vs-Navigation-District jurisdictional split

Known issues

data:gaps-present

Other cities in this state