Overview
- R-2 is workhorse district — SF, two-family, and MF together with contextual front setback [c§120-23]
- Attached garages must be set back 10 ft further than principal structure front (snout house prevention) [c§120-23]
- Corner lots in R-2: both street yards = front yards [c§120-23]
+ 7 more in Quirks & notes
Districts
| Code | Name | Category | Min lot | Height | Coverage | FAR | Du/ac | Parking | Setbacks F/S/R |
|---|---|---|---|---|---|---|---|---|---|
| R-1 | Low-Density Residential | res_sf | 5,000 sf[4] | 35 ft[5] | — | — | — | — | 20[1] / 5[2] / 10[3] |
| R-2 | Medium-Density Residential | res_sf | 5,000 sf[9] | 35 ft[10] | — | — | — | — | 20[6] / 5[7] / 10[8] |
| R-3 | High-Density Residential | res_mf | 5,000 sf[14] | 45 ft[15] | — | — | — | — | 20[11] / 10[12] / 20[13] |
| C-1 | Neighborhood Center | com | — | —[19] | — | — | — | — | 2[16] / —[17] / —[18] |
| C-2 | Community Center | com | — | 20 ft[23] | — | — | — | — | —[20] / —[21] / —[22] |
| C-3 | Regional Destination | com | — | —[27] | — | — | — | — | 0[24] / 0[25] / 0[26] |
| M-1 | Industrial | ind | — | —[31] | — | — | — | — | —[28] / —[29] / —[30] |
| O-S | Open Space | spec | — | — | — | — | — | — | — / — / — |
Confidence: confirmed partial under review not found
Overlays
Applied over C-1 or R-3 near sensitive areas (R-1/R-2 residential, Open Space, Preservation Districts, landmarks, historic properties, parks, critical environmental areas)
| max_stories | 3 |
|---|
Locally designated historic preservation districts (East Avenue, Corn Hill, Maplewood, Park Avenue, and others)
| review | Certificate of Appropriateness required for exterior improvements |
|---|---|
| authority | Preservation Board per c§120-194 |
Multiple designated village center nodes throughout the city
| review | Certificates of zoning compliance required for exterior improvements |
|---|
Downtown Rochester core
| sub_districts | 6 |
|---|---|
| form_based | True |
| parking_min_exempt | True |
| parking_maximums_apply | True |
| article_xx_exempt | True |
| marina_district_solar_pv_permitted_roofing | True |
Site-specific properties rezoned to PDD status
| approval | City Council following Planning Commission recommendation |
|---|---|
| minor_adjustments | Manager of Zoning may approve |
State preemptions
Non-applicable laws (1)
Adopted building codes
Statewide except NYC
Click a code label to open its state-by-state adoption atlas.
Quirks & notes
- R-2 is workhorse district — SF, two-family, and MF together with contextual front setback [c§120-23]
- Attached garages must be set back 10 ft further than principal structure front (snout house prevention) [c§120-23]
- Corner lots in R-2: both street yards = front yards [c§120-23]
- Center City District exempt from Article XX (Requirements Applying to All Districts) [c§120-150 intro]
- Parking maximums (not just minimums) for nonresidential uses — advanced for 2003 adoption
- All CCD uses exempt from minimum parking requirements [c§120-65]
- O-LH creates selective 3-story cap on C-1 and R-3 near sensitive areas [c§120-118.1]
- Zoning Alignment Project (ZAP) underway to update 2003 code aligned with Rochester 2034 Comp Plan; adoption timeline unconfirmed
- Solar energy systems <= 1/2 story above roof exempt from max height [c§120-196]; collectors may be in required setbacks [c§120-197]
- Hybrid code: Euclidean base districts + form-based CCD (downtown) + city-wide design guidelines (Article XIX)
Formulas
Definitions
- height
- Grade to highest point of structure. §120
- lot_coverage
- Building footprint / lot area. Repealed for commercial/industrial 2010.
- far
- du_ac
- impervious_cover
- setback_front
- Front property line to nearest building face. Contextual average in R-1/R-2.
- setback_side
- Side property line to nearest building face.
- setback_rear
- Rear property line to nearest building face.
- parking
- Spaces per dwelling unit unless noted.
Capacity calculations
- max_footprint_sf
lot_area_sf * lot_coverage- buildable_width_ft
lot_width_ft - setback_side_ft * 2- buildable_depth_ft
lot_depth_ft - setback_front_ft - setback_rear_ft- buildable_envelope_sf
buildable_width_ft * buildable_depth_ft- max_stories_approx
max_height_ft / 10
Massing explorer
Interactive 3D comparison across every district. Drag to orbit, scroll to zoom, use the slider to walk districts, and toggle applicable overlays in the right-side panel.
| District | Category | Height | FAR | Coverage | Setbacks | Parking | Density | Min lot | Overlays |
|---|
Sources & references
- [1] §120-19
- [2] §120-19
- [3] §120-19
- [4] §120-19
- [5] §120-19
- [6] §120-23
- [7] §120-23
- [8] §120-23
- [9] §120-23
- [10] §120-23
- [11] §120-30
- [12] §120-30
- [13] §120-30
- [14] §120-30
- [15] §120-30
- [16] §120-36
- [17] §120-36
- [18] §120-36
- [19] §120-36
- [20] §120-40
- [21] §120-40
- [22] §120-40
- [23] §120-40
- [24] §120-50
- [25] §120-50
- [26] §120-50
- [27] §120-50
- [28] §120-94
- [29] §120-94
- [30] §120-94
- [31] §120-94
Research status
Publication gates
| primary url present | passed | |
|---|---|---|
| no aggregator cited | passed | |
| confidence tags full form | passed | |
| overlays have parameters trigger confidence | passed | |
| preempt section city specific | passed |
Data quality
- C-1 side/rear setbacks and height not confirmed
- C-2 setbacks not confirmed
- C-3 height not specified in extracted source
- M-1 side/rear setbacks and height not specified
- CCD sub-district dimensional parameters not extracted
- O-S dimensional standards not specified
- Zoning Alignment Project replacement timeline unconfirmed
Known issues
Other cities in this state
Nearest-alphabetical profiles. Click through to compare zoning patterns side-by-side.