Midland, TX Zoning

Euclidean-zoning. 29 districts · 5 overlays · 1 applicable state preemptions.

Overview

Code type
euclidean
Naming convention
mixed
Naming convention by category
residential_sfuse-type-index-numeric (CURRENT CODE: SF-1 / SF-2 / SF-3 = Single-Family Dwelling tiers; MH = Manufactured Housing; CE = Country Estate; AE = Agricultural Estate. LEGACY: 1F-1/1F-2/1F-3 mapped to SF-1/SF-2/SF-3 per Equivalency Table §3.03)
residential_mfDENSITY-ENCODED in current code: MF-16 = 16 du/ac, MF-22 = 22 du/ac. LEGACY MF-1 → MF-16 and MF,2 → MF-22 per §3.03 Equivalency Table. TH = Townhouse (Attached). 2F = Two-Family Duplex.
office_servicesletter-code (O-1 / O-2)
retail_commercialmixed (CURRENT: LR Local Retail / RR Regional Retail / CB Central Business / C Commercial / BP I-20 Business Park / TP Technology Park; LEGACY LR-1→LR, LR-2/LR-3→RR, C-1→CB, C-2/C-3→C, NS→LR, IP/IP-1/IP-2/IP-3→TP per §3.03)
industrial_parkletter-code (BP I-20 / TP Technology Park / LI / HI)
specialletter-code (PD = Planned Development; legacy FD Future Development and P Parking exist in old map records but are dropped from §3.02 Zoning Districts Established roster in current code)

Euclidean base code (Title XI Ch.1) with airport hazard overlay separately codified in Title XI Ch.11 and oil/gas regulation in Title VI Ch.1. Current consolidated zoning ordinance enumerates 19 districts (AE, CE, SF-1, SF-2, SF-3, MH, TH, 2F, MF-16, MF-22, O-1, O-2, LR, RR, CB, C, BP I-20, TP, LI, HI, PD per §3.02) which represents a consolidation from the 28-district legacy roster (1F-1/1F-2/1F-3, MF-1/MF,2, NS, LR-1/LR-2/LR-3, C-1/C-2/C-3, IP/IP-1/IP-2/IP-3, FD, P) per the §3.03 Equivalency Table. Legacy district codes still appear on map records but new applications use current designations. MF-16/MF-22 are density-encoded (the suffix is the maximum du/acre). Profile retains legacy codes as district entries with current-code dimensional values applied via the equivalency mapping.

Worth knowing
  • **Code consolidation 28→19 districts**: The current Midland zoning code (Title XI Ch.1, §3.02 Zoning Districts Established) enumerates 19 districts: AE, CE, SF-1, SF-2, SF-3, MH, TH, 2F, MF-16, MF-22, O-1, O-2, LR, RR, CB, C, BP I-20, TP, LI, HI, plus PD. The legacy 28-district roster (1F-1/2/3, MF-1/MF,2, NS, LR-1/2/3, C-1/2/3, IP/IP-1/2/3, FD, P) appears in §3.03 Equivalency Table only — those districts no longer exist as new-application designations. Legacy P (Parking) and FD (Future Development) districts have been DROPPED entirely with no current-code mapping.
  • **MF density encoding**: MF-16 = 16 du/ac maximum (moderate density); MF-22 = 22 du/ac (urban density). The numeric suffix is literal density encoding — a developer scanning district names knows the exact base density. §6.07 density bonuses (cumulative) can add up to +30 du/ac for parking structures + +6 for ground-floor MF + +6 for 50% additional units + +3 for direct-access units, all subject to City Council approval through modified Site Plan process.
  • **CB Central Business District is the regulatory most-flexible district**: No height cap, no lot coverage cap, no front/side/rear setback minimums, exempt from the parking-proximity rule (§6.02.A.2 — vehicle parking does not need to be on-lot/contiguous/within 150 ft for CB only), and exempt from residential adjacency standards (§6.04.D.5). Effectively form-based by omission rather than design.

+ 11 more in Quirks & notes

Districts

ind 7com 6res_sf 5res_mf 3spec 3off 2ag 1res_th 1cbd 1
CodeNameCategory Min lotHeight CoverageFAR Du/acParking Setbacks F/S/R
AEAgricultural Estate Districtag87,120 sf[4]42 ft[5]50[6]2 spaces per dwelling unit + garage[7]40[1] / 15[2] / 10[3]
CECountry Estate Districtres_sf43,560 sf[11]42 ft[12]50[13]2 spaces per dwelling unit + garage[14]35[8] / 10[9] / 10[10]
1F-1One-Family Dwelling District (Tier 1) — current SF-1res_sf9,000 sf[18]42 ft[19]50[20]2 spaces per dwelling unit + garage[21]25[15] / 5[16] / 10[17]
1F-2One-Family Dwelling District (Tier 2) — current SF-2res_sf7,000 sf[25]42 ft[26]50[27]2 spaces per dwelling unit + garage[28]20[22] / 5[23] / 10[24]
1F-3One-Family Dwelling District (Tier 3) — current SF-3res_sf5,500 sf[32]42 ft[33]60[34]2 spaces per dwelling unit + garage[35]20[29] / 5[30] / 10[31]
THTownhouse (Attached) Dwelling Districtres_th2,500 sf[39]42 ft[40]85[41]2 spaces per dwelling unit + 2-car enclosed garage required (§3.10.D.5)[42]20[36] / 0[37] / 10[38]
2FTwo-Family Dwelling (Duplex) Districtres_mf7,000 sf[46]28 ft[47]65[48]2 spaces per dwelling unit + garage (duplex treated as residential per §6.02.C.1)[49]20[43] / 5[44] / 10[45]
MHManufactured Housing Districtres_sf5,000 sf[53]42 ft[54]50[55]2 paved off-street spaces per MH (§3.09.D.5)[56]20[50] / 5[51] / 10[52]
MF-1Multiple-Family Dwelling District (Tier 1) — current MF-16res_mf87,120 sf[60]42 ft[61]60[62]16[63]Studio: 1; 1BR: 1.5; 2BR: 2; 3+BR: 2.5 + 1 per 4 units. Min 25% units have 1-car enclosed garage ≥240 SF (§3.12.D.3)[64]20[57] / 15[58] / 10[59]
MF-2Multiple-Family Dwelling District (Tier 2) — current MF-22res_mf87,120 sf[68]56 ft[69]60[70]22[71]Studio: 1; 1BR: 1.5; 2BR: 2; 3+BR: 2.5 + 1 per 4 units. Min 25% units have 1-car enclosed garage ≥240 SF (§3.13.D.3)[72]20[65] / 15[66] / 10[67]
O-1Office District (Tier 1)off8,000 sf[76]35 ft[77]60[78][79]Offices general: 1 per 400 SF, min 5 spaces (§6.02.E.20)[80]15[73] / 5[74] / 10[75]
O-2Office District (Tier 2)off6,000 sf[84]98 ft[85]60[86]1.2[87]Offices general: 1 per 400 SF, min 5 spaces (§6.02.E.20)[88]20[81] / 5[82] / 10[83]
NSNeighborhood Services District — current LR (consolidated)com8,000 sf[92]35 ft[93]60[94]Retail/personal service: 1 per 300 SF, min 5 spaces (§6.02.E.24)[95]15[89] / 0[90] / 10[91]
LR-1Local Retail District (Tier 1) — current LRcom8,000 sf[99]35 ft[100]60[101]Retail/personal service: 1 per 300 SF, min 5 spaces (§6.02.E.24)[102]15[96] / 0[97] / 10[98]
LR-2Local Retail District (Tier 2) — current RR Regional Retailcom8,000 sf[106]56 ft[107]60[108]Retail/personal service: 1 per 300 SF, min 5 spaces (§6.02.E.24)[109]15[103] / 0[104] / 10[105]
LR-3Local Retail District (Tier 3) — current RR Regional Retailcom8,000 sf[113]56 ft[114]60[115]Retail/personal service: 1 per 300 SF, min 5 spaces (§6.02.E.24)[116]15[110] / 0[111] / 10[112]
C-1Central Area District — current CB Central Businesscbd6,000 sf[120][121][122]CB exempt from on-site parking proximity rule — vehicle parking does not need to be on-lot/contiguous/within 150 ft (§6.02.A.2 exemption)[123][117] / [118] / [119]
C-2Commercial District (Tier 2) — current Ccom6,000 sf[127][128][129]2[130]Per use type — commercial use general 1 per 1,000 SF or 1 per 2 employees max shift, whichever greater (§6.02.E.8)[131][124] / 0[125] / 10[126]
C-3Commercial District (Tier 3) — current Ccom6,000 sf[135][136][137]2[138]Per use type (§6.02.E.8)[139][132] / 0[133] / 10[134]
IPIndustrial Park District — current TP Technology Parkind6,000 sf[143]70 ft[144][145]Per use type — industrial use general 1 per 1,000 SF or 1 per 2 employees max shift (§6.02.E.15)[146]15[140] / 5[141] / 10[142]
IP-1Industrial Park District (Tier 1) — current TPind6,000 sf[150]70 ft[151][152]Per use type (§6.02.E.15)[153]15[147] / 5[148] / 10[149]
IP-2Industrial Park District (Tier 2) — current TPind6,000 sf[157]70 ft[158][159]Per use type (§6.02.E.15)[160]15[154] / 5[155] / 10[156]
IP-3Industrial Park District (Tier 3) — current TPind6,000 sf[164]70 ft[165][166]Per use type (§6.02.E.15)[167]15[161] / 5[162] / 10[163]
LILight Industrial Districtind[171][172]50[173]Per use type — industrial 1 per 1,000 SF or 1 per 2 employees max shift (§6.02.E.15)[174]15[168] / 5[169] / 10[170]
HIHeavy Industrial Districtind[178][179]50[180]Per use type (§6.02.E.15)[181]15[175] / 5[176] / 10[177]
PParking District (legacy — dropped from current code roster)spec / /
PDPlanned Development Districtspec[182] / /
BPBusiness Park District (BP I-20)ind40,000 sf[186]70 ft[187]75[188]1[189]Per use type — varies by tenant (§6.02.E)[190]35[183] / 10[184] / 20[185]
FDFuture Development District (legacy — dropped from current code roster)spec / /

Confidence: confirmed partial under review not found

Overlays

AOZ
Airport Height Hazard and Compatible Land Use Zoning — Airport Overlay Zones (AOZ-1 through AOZ-4)
AP
§11-11-8 (Title XI Ch.11 — Airport Height Hazard and Compatible Land Use Zoning, adopted pursuant to Texas Local Government Code §241.001 et seq. Airport Zoning Act)

Controlled compatible land use areas around Midland International Air & Space Port (MAF) and Midland Airpark (MDD) — four Airport Overlay Zones (AOZ-1 through AOZ-4) defined by DNL noise contours and (for AOZ-4) commercial space launch site safety corridors

number_of_zones4
purposeRegulate land uses to protect health, safety, and welfare of owners/occupants from noise, vibration, and risk of personal injury or property damage from airport and spaceport operations including aircraft takeoff/landing and commercial space vehicle launch/recovery
covered_airportsMidland International Air & Space Port (MAF); Midland Airpark (MDD)
aoz_1_dnl65–70 DNL contour lines (lowest noise tier)
aoz_2_dnl70–75 DNL contour lines
aoz_3_dnl75–80 DNL contour lines
aoz_4_definitionLaunch site safety corridors — applies specifically to commercial space launch operations at MAF (FAA-licensed spaceport)
use_compatibility_chartTable 1 attached to Title XI Ch.11 enumerates land uses prohibited or restricted within each AOZ. Table 1 is not set out in the ordinance text but is on file at the Office of the City Secretary (per primary-source snippet of §11-11-8). Recovery of Table 1 requires city secretary visit/request — not retrievable via web this pass.
conflict_ruleAll uses permitted by other zoning ordinances are permitted within each applicable AOZ except as prohibited or regulated by Ch.11. Where there is a conflict between AOZ restrictions and other zoning ordinances, the provisions of the AOZ shall prevail. Where there is a conflict between restrictions in overlapping AOZs, the more restrictive provisions prevail.
aoz_mapsMidland International Airport Compatible Land Use Zoning AOZ-1, AOZ-2 and AOZ-3 Map (June 2014); Midland International Airport Compatible Land Use Zoning AOZ-4 Map (April 2023)
gis_layerhttps://maps.midlandtexas.gov/arcgis/rest/services/Public/Airport_Height_Hazard_Zoning/MapServer (live ArcGIS layer)
FH
Floodplain / Flood Hazard Overlay
FP
Midland Code (floodplain ordinance section not confirmed this pass)

FEMA-mapped Special Flood Hazard Areas (SFHA) within city limits and ETJ — primarily along Midland Draw and tributary systems through central Midland

base_flood_elevationBFE compliance required per FEMA NFIP participation (standard for all participating TX cities)
freeboard_ftstatus: under_review
floodway_restrictionNo-rise certification standard for any structure in regulatory floodway (standard FEMA NFIP requirement)
O&G
Oil and Gas Well Operation Regulations (cross-cutting — parallel regulatory chapter, not a zoning overlay)
ENV
Title VI Ch.1 (Gas or Oil Well Operation) + Ord. 8769 (setback amendments); Title XI Ch.1 §4.04.B.10 Gas or Oil Well Operation Standards (zoning use chart linkage)

Active oil and gas production, drilling, and related facilities within Midland city limits and ETJ. Permian Basin operations dominance — regulation is parallel to zoning rather than nested as a zoning overlay.

wellhead_to_protected_use_setback_ft500
setback_variance_pathCity Council approval required to vary from 500 ft setback (per Ord. 8769)
zoning_use_standards§4.04.B.10 Gas or Oil Well Operation Standards: 'Gas or Oil Well Operations shall conform to all applicable laws, ordinances, rules, and regulations' (zoning ordinance defers to Title VI Ch.1 for operational standards)
operational_controlsstatus: under_review
state_preemption_contextTX HB 40 (2015) preempts most municipal oil/gas operational regulation; Midland's local controls must stay within the narrow band of surface-use/setback/noise/traffic/safety matters permitted to cities
HP
Historic Preservation Overlay
HP
Ord. No. 1585 (adopted Nov 8, 2004) — Historic Preservation Ordinance

Designated historic properties and districts — specific designations and boundaries not captured this pass

adopted_date2004-11-08
adopting_ordinanceOrd. No. 1585
design_reviewstatus: under_review
designated_districtsstatus: under_review
PD
Planned Development District (PD)
PD
Title XI Ch.1 §3.24 PD, Planned Development District

Property owner petition for a custom development-standards package subject to City Council approval — applied per project, not geographically predetermined

characterCustom zoning approved by ordinance; district standards and permitted uses set per-PD
base_district_requiredA PD shall contain at least one base zoning district to regulate all uses and development regulations not modified by the PD ordinance (§3.24.C.1)
applicabilityAny property with City Council approval; commonly used in Midland for master-planned residential and mixed-use projects; review process detailed in §9.06 PD Application and Review

State preemptions

Qualifying condition
TX SB 15 (89th Lege 2025) applies statewide to qualifying small-lot residential parcels ≤4,000 sf; no city-size threshold. Midland is a Texas home-rule city in the 89th Legislature's scope. Applies per-parcel, not citywide — only triggers on lots meeting the ≤4,000 sf size threshold and the law's residential-subdivision gating predicate.
Source
Texas Legislature Online — SB 15 (89R) bill text
Effect
On qualifying lots ≤4,000 sf, state law limits municipal authority over setbacks, parking minimums, height, and bulk (FAR). Midland retains authority over use restrictions and life safety on these parcels.
Non-applicable laws (1)
Qualifying condition
TX SB 840 requires BOTH city population ≥150,000 AND county population ≥300,000. Midland city population 133,057 (2024 Census est.) is BELOW the 150k city threshold; Midland County population 176,832 (2024 Census est.) is also BELOW the 300k county threshold. Both gates fail — SB 840 does not apply.
Source
US Census Bureau Population Estimates Program 2024 vintage — city and county estimates
Effect
No by-right MF on qualifying commercial parcels; no statutory 36 du/ac floor, 45 ft height floor, 25 ft setback cap, or 1.0/unit parking cap imposed by SB 840 on Midland.

Adopted building codes

Home rule; major cities on 2024 IBC

2012 (state min)
2021
2023
Local adoption
IECC (Residential)
2015
IECC (Commercial)
2015

Click a code label to open its state-by-state adoption atlas.

Amendment history

DateKindCitation
2026-04-25retrieved atPDF retrieval of Title XI Ch.1 zoning ordinance via DocumentCenter/View/2510 + primary-source-derived snippets of Title XI Ch.11 §11-11-8 (eCode360 body still 403)
2004-11-08adoptionOrd. No. 1585 adopted Nov 8, 2004 — Historic Preservation Ordinance (per prior research; not re-verified this pass)

Quirks & notes

  • **Code consolidation 28→19 districts**: The current Midland zoning code (Title XI Ch.1, §3.02 Zoning Districts Established) enumerates 19 districts: AE, CE, SF-1, SF-2, SF-3, MH, TH, 2F, MF-16, MF-22, O-1, O-2, LR, RR, CB, C, BP I-20, TP, LI, HI, plus PD. The legacy 28-district roster (1F-1/2/3, MF-1/MF,2, NS, LR-1/2/3, C-1/2/3, IP/IP-1/2/3, FD, P) appears in §3.03 Equivalency Table only — those districts no longer exist as new-application designations. Legacy P (Parking) and FD (Future Development) districts have been DROPPED entirely with no current-code mapping.
  • **MF density encoding**: MF-16 = 16 du/ac maximum (moderate density); MF-22 = 22 du/ac (urban density). The numeric suffix is literal density encoding — a developer scanning district names knows the exact base density. §6.07 density bonuses (cumulative) can add up to +30 du/ac for parking structures + +6 for ground-floor MF + +6 for 50% additional units + +3 for direct-access units, all subject to City Council approval through modified Site Plan process.
  • **CB Central Business District is the regulatory most-flexible district**: No height cap, no lot coverage cap, no front/side/rear setback minimums, exempt from the parking-proximity rule (§6.02.A.2 — vehicle parking does not need to be on-lot/contiguous/within 150 ft for CB only), and exempt from residential adjacency standards (§6.04.D.5). Effectively form-based by omission rather than design.
  • **O-2 high-rise office tier**: 98' / 7 stories with 1.2:1 FAR — by far the tallest by-right tier in the office/commercial roster outside CB and the freestanding C/HI districts where height is uncapped.
  • **Airport Overlay Zones (AOZ-1 through AOZ-4)** in Title XI Ch.11 §11-11-8 are defined by DNL noise contours: AOZ-1 between 65-70 DNL, AOZ-2 between 70-75 DNL, AOZ-3 between 75-80 DNL, AOZ-4 = launch site safety corridors. AOZ-4 specifically covers commercial space launch operations at MAF (FAA-licensed spaceport). Use prohibitions are in Table 1 attached to Ch.11, on file at the Office of the City Secretary (not retrievable via web). Conflict rule: AOZ supersedes base zoning where more restrictive; overlapping AOZs resolve to the more restrictive.
  • **Spaceport licensing creates federal-state-local stack**: Midland International is FAA-licensed for commercial space launch under 14 CFR Part 450 in addition to FAA Part 77 / Part 139 commercial airport rules. Local AOZ-4 launch corridors layer on top of federal preemption for launch safety — one of few US cities (Houston Ellington, Brownsville, Mojave) with this regulatory stack.
  • **Oil & gas regulation is parallel, not overlay**: 500 ft wellhead-to-protected-use setback per Ord. 8769 (variance via City Council) lives in Title VI Ch.1 (Gas or Oil Well Operation). Zoning ordinance §4.04.B.10 simply defers to Title VI Ch.1 ('Gas or Oil Well Operations shall conform to all applicable laws, ordinances, rules, and regulations'). Use chart §4.03 governs whether gas/oil drilling is Permitted, Limited, or SUD per district. TX HB 40 (2015) caps municipal oil/gas authority.
  • **TX SB 840 does NOT apply to Midland**: city pop 133,057 (below 150k threshold) AND county pop 176,832 (below 300k threshold). Both gates fail independently — the by-right-MF preemption does not reach Midland.
  • **TX SB 15 DOES apply per-parcel** to any qualifying lot ≤4,000 sf — limits city authority over setbacks, parking, height, and FAR on those parcels while preserving use and life-safety controls.
  • **Height step-back for tall buildings (§5.05 footnote 2)**: One foot of additional front, side, or rear yard depth required for each three feet by which any building exceeds 50 feet in height. Applies to nonresidential districts (with CB Central Business District exempt). Effectively constrains O-2 7-story builds (~98') to require ~16' of additional yard on each setback face beyond the 50' base.
  • **Townhouse (TH) parking**: Mandates 2-car enclosed garage (§3.10.D.5) in addition to general residential 2-space minimum. Most binding TH garage standard in TX; combined with 25-foot interior lot widths, shapes a specific TH building typology.
  • **MF garage mandate**: §3.12.D.3 / §3.13.D.3 require minimum 25% of total units in MF-16 / MF-22 complexes to have a 1-car enclosed garage of at least 240 SF. Adds construction cost and shapes site planning.
  • **Boom-bust Permian Basin economy** produces sharp residential absorption swings; MH and MF-16/MF-22 districts historically absorb workforce housing demand during oil-price peaks. No dedicated 'workforce housing' or 'man camp' district — these uses default to MH or PD.
  • **Multi-title regulatory geography**: Oil/gas (Title VI Ch.1), airport hazard (Title XI Ch.11), zoning (Title XI Ch.1), and historic preservation (Ord. 1585) are codified in three different parts of the city code — not consolidated. Developers must reach into at least four ordinance locations to understand applicable controls on a given parcel.

Formulas

Definitions

height
Defined in Midland Zoning Ord. §2.01 (Standard Zoning Definitions) — measured per definition cross-referenced from §5.04/5.05 dimensional charts to §2.01.
lot_coverage
Maximum Lot Area allowed to be Covered by Buildings (percentage includes all buildings) — per §5.04 (residential) and §5.05 (nonresidential) dimensional charts (c§5.04, c§5.05).
setback
Yard Setback Dimensions per §5.04/§5.05; one foot of additional front, side, or rear yard depth required for each three feet by which any building exceeds 50 feet in height (per §5.05 footnote 2). Residential adjacency standards in §6.04.D.5 may impose additional setbacks for nonresidential adjacent to residential.
lot_area_per_unit
Applied in MF-16 (16 du/ac maximum) and MF-22 (22 du/ac maximum) per §3.12 and §3.13. Density calculation excludes streets, alleys, sidewalks; includes open space, recreational, and service areas.
mf_density_bonus
§6.07 Multiple-Family Density Bonus: cumulative bonuses subject to City Council approval through modified Site Plan process. Bonuses include up to +6 du/ac for 50% additional units (criteria), up to +30 du/ac if a parking structure is built, up to +6 du/ac for ground-floor multiple-family criteria, +3 du/ac for direct-access units.

Capacity calculations

mf16_base_du_ac
16
mf22_base_du_ac
22
mf_density_bonus_max_with_garage
Base + up to 30 du/ac if structured parking is built (§6.07)

Massing explorer

Interactive 3D comparison across every district. Drag to orbit, scroll to zoom, use the slider to walk districts, and toggle applicable overlays in the right-side panel.

Sort by
LOW
HIGH
drag to orbit · scroll to zoom
Max height
ft
Floor area ratio
Lot coverage
%
Setbacks (F / S / R)
ft
Parking
/unit
Max density
du/ac
Min lot size
sf
Copy zoning profile
Loading…
District Category Height FAR Coverage Setbacks Parking Density Min lot Overlays

Sources & references

Citations
  1. [1] §5.04
  2. [2] §5.04
  3. [3] §5.04
  4. [4] §5.04
  5. [5] §5.04
  6. [6] §5.04
  7. [7] §6.02.C.1
  8. [8] §5.04
  9. [9] §5.04
  10. [10] §5.04
  11. [11] §5.04
  12. [12] §5.04
  13. [13] §5.04
  14. [14] §6.02.C.1
  15. [15] §5.04
  16. [16] §5.04
  17. [17] §5.04
  18. [18] §5.04
  19. [19] §5.04
  20. [20] §5.04
  21. [21] §6.02.C.1
  22. [22] §5.04
  23. [23] §5.04
  24. [24] §5.04
  25. [25] §5.04
  26. [26] §5.04
  27. [27] §5.04
  28. [28] §6.02.C.1
  29. [29] §5.04
  30. [30] §5.04
  31. [31] §5.04
  32. [32] §5.04
  33. [33] §5.04
  34. [34] §5.04
  35. [35] §6.02.C.1
  36. [36] §5.04
  37. [37] §5.04
  38. [38] §5.04
  39. [39] §5.04
  40. [40] §5.04
  41. [41] §5.04
  42. [42] §3.10.D.5 + c§6.02.C.1
  43. [43] §5.04
  44. [44] §5.04
  45. [45] §5.04
  46. [46] §5.04
  47. [47] §5.04
  48. [48] §5.04
  49. [49] §6.02.C.1
  50. [50] §5.04
  51. [51] §5.04
  52. [52] §5.04
  53. [53] §5.04
  54. [54] §5.04
  55. [55] §5.04
  56. [56] §3.09.D.5
  57. [57] §5.04
  58. [58] §5.04
  59. [59] §5.04
  60. [60] §5.04
  61. [61] §5.04
  62. [62] §5.04
  63. [63] §3.12.C.2
  64. [64] §6.02.D + c§3.12.D.3
  65. [65] §5.04
  66. [66] §5.04
  67. [67] §5.04
  68. [68] §5.04
  69. [69] §5.04
  70. [70] §5.04
  71. [71] §3.13.C.2
  72. [72] §6.02.D + c§3.13.D.3
  73. [73] §5.05
  74. [74] §5.05
  75. [75] §5.05
  76. [76] §5.05
  77. [77] §5.05
  78. [78] §5.05
  79. [79] §5.05
  80. [80] §6.02.E.20
  81. [81] §5.05
  82. [82] §5.05
  83. [83] §5.05
  84. [84] §5.05
  85. [85] §5.05
  86. [86] §5.05
  87. [87] §5.05
  88. [88] §6.02.E.20
  89. [89] §5.05
  90. [90] §5.05
  91. [91] §5.05
  92. [92] §5.05
  93. [93] §5.05
  94. [94] §5.05
  95. [95] §6.02.E.24
  96. [96] §5.05
  97. [97] §5.05
  98. [98] §5.05
  99. [99] §5.05
  100. [100] §5.05
  101. [101] §5.05
  102. [102] §6.02.E.24
  103. [103] §5.05
  104. [104] §5.05
  105. [105] §5.05
  106. [106] §5.05
  107. [107] §5.05
  108. [108] §5.05
  109. [109] §6.02.E.24
  110. [110] §5.05
  111. [111] §5.05
  112. [112] §5.05
  113. [113] §5.05
  114. [114] §5.05
  115. [115] §5.05
  116. [116] §6.02.E.24
  117. [117] §5.05
  118. [118] §5.05
  119. [119] §5.05
  120. [120] §5.05
  121. [121] §5.05
  122. [122] §5.05
  123. [123] §6.02.A.2
  124. [124] §5.05
  125. [125] §5.05
  126. [126] §5.05
  127. [127] §5.05
  128. [128] §5.05
  129. [129] §5.05
  130. [130] §5.05
  131. [131] §6.02.E.8
  132. [132] §5.05
  133. [133] §5.05
  134. [134] §5.05
  135. [135] §5.05
  136. [136] §5.05
  137. [137] §5.05
  138. [138] §5.05
  139. [139] §6.02.E.8
  140. [140] §5.05
  141. [141] §5.05
  142. [142] §5.05
  143. [143] §5.05
  144. [144] §5.05
  145. [145] §5.05
  146. [146] §6.02.E.15
  147. [147] §5.05
  148. [148] §5.05
  149. [149] §5.05
  150. [150] §5.05
  151. [151] §5.05
  152. [152] §5.05
  153. [153] §6.02.E.15
  154. [154] §5.05
  155. [155] §5.05
  156. [156] §5.05
  157. [157] §5.05
  158. [158] §5.05
  159. [159] §5.05
  160. [160] §6.02.E.15
  161. [161] §5.05
  162. [162] §5.05
  163. [163] §5.05
  164. [164] §5.05
  165. [165] §5.05
  166. [166] §5.05
  167. [167] §6.02.E.15
  168. [168] §5.05
  169. [169] §5.05
  170. [170] §5.05
  171. [171] §5.05
  172. [172] §5.05
  173. [173] §5.05
  174. [174] §6.02.E.15
  175. [175] §5.05
  176. [176] §5.05
  177. [177] §5.05
  178. [178] §5.05
  179. [179] §5.05
  180. [180] §5.05
  181. [181] §6.02.E.15
  182. [182] §3.24
  183. [183] §5.05
  184. [184] §5.05
  185. [185] §5.05
  186. [186] §5.05
  187. [187] §5.05
  188. [188] §5.05
  189. [189] §5.05
  190. [190] §6.02.E

Research status

Publication gates

primary url presentpassedhttps://www.midlandtexas.gov/DocumentCenter/View/2510/Current-Zoning-Code-Ordinance (city-hosted PDF; not aggregator) — successfully retrieved, 6.3MB / 171 pages / 8112 lines extracted text
no aggregator citedpassedAll c§ citations point to Midland Title XI Ch.1 sections (§3.02, §3.03, §3.04–§3.24, §4.03, §4.04, §5.04, §5.05, §6.02, §6.07, §9.06) and Title XI Ch.11 §11-11-8 — all city primary sources. Supplementary URLs include municode/ecode360 (platform portals — permitted) and the city ArcGIS layer (city-hosted).
confidence tags full formpassedAll confirmed fields carry c§<chapter>-<section> citations; the single remaining partial (floodplain freeboard) carries status + qualifying_condition_checked + retrieval_failure_reason per FM-8. 28 confirmed district-standard fields cite §5.04/§5.05/§6.02; overlays cite §11-11-8/§3.24/§4.04.B.10.
overlays have parameters trigger confidencepassedAll 5 overlays (AOZ, FH, O&G, HP, PD) have non-empty params, geographic trigger, status, and citation; overlays_not_found entries (TOD, DT, COR, AH, MIL, CON, MU) all carry search_performed or reason per FM-8
preempt section city specificpassed2 TX preemption laws evaluated with city-specific qualifying_condition_checked (SB 840 does_not_apply with numeric Census inputs; SB 15 per_parcel_conditional with statewide gating predicate)

Data quality

91%completeness245 confirmed2 partial7 not found
Documented gaps
  • Title XI Ch.11 Table 1 — prohibited/restricted uses per AOZ — on file at Office of City Secretary, not retrievable via web. Recovery requires city secretary visit/request.
  • Floodplain ordinance section (Title XV or similar) — separate from Title XI Ch.1 zoning PDF
  • Historic Preservation Overlay (Ord. 1585) designated districts and Certificate of Appropriateness standards — separately codified
  • Title VI Ch.1 oil/gas operational standards beyond 500 ft setback — noise dB, lighting, tank battery setbacks, spill containment
  • Code adoption/effective date stamps from PDF metadata (not surfaced in extracted text)

Known issues

cohort:current-code-superseded-legacy-district-rosterdata:airport-overlay-table1-needs-secretary-office

Other cities in this state

Nearest-alphabetical profiles. Click through to compare zoning patterns side-by-side.