Overview
| res_sf | lot-size-encoded (R1-15A = plat-defined; R1-15 = 15,000 sf; R1-10/R1-10A = 10,000 sf; R1-7.5 = 7,500 sf; R1-E = beach estate 67,500 sf; RE = rural estate 2.25 acre) |
|---|---|
| res_mf | density-encoded (R3-6 = 6 du/ac, R3-12 = 12 du/ac, R3-15 = 15 du/ac, R3-18 = 18 du/ac with named-neighborhood variants for Coquina Sands and Moorings) |
| com | letter-code (HC Highway, C1 Retail Shopping, C1-A Commercial Core, C2 General, C2-A Waterfront, C3 Heavy, C4 Airport) |
| cbd | letter-code (D Downtown) |
| other | letter-code (I Industrial, M Medical, O Office, PD Planned Development, PS Public Service, C/TC Conservation, BP Business Park) |
Naples uses a Euclidean base code structured in Chapter 58 of the City Code of Ordinances. Article II (Zoning Districts) enumerates base districts as numbered Divisions; Article III (Special Overlay Districts) contains overlays. Solid-tier retrieval confirmed structural map: Div. 2 RE Rural Estates (§58-51..58-60); Div. 3 R1-E Beach Estate (§58-81..58-90); Div. 4 R1-15A (§58-111..58-124); Div. 5 R1-15 (§58-141..58-150); Div. 6 R1-10 (§58-171..58-180); Div. 7 R1-10A (§58-201..58-211); Div. 8 R1-7.5 (§58-231..58-240); Div. 9 R3-6 (§58-261..58-271); Div. 10 R3-12 (§58-291..58-301); Div. 11 R3T-12 (§58-321..58-331); Div. 12 R3-15 (§58-351..58-361); Div. 13 R3-15 Coquina Sands (§58-381..58-392); Div. 14 R3-15 Moorings (§58-411..58-422); Div. 15 R3-18 (§58-441..58-451); Div. 16 R3T-18 (§58-471..58-481); Div. 17 HC (§58-501..58-512); Div. 18 C1 (§58-531..58-541); Div. 19 C1-A (§58-561..58-571); Div. 20 C2 (§58-591..58-601); Div. 21 C2-A (§58-621..58-631); Div. 22 C3 (§58-651..58-660); Div. 23 C4 (§58-681..58-691); Div. 24 I (§58-711..58-719); Div. 25 M (§58-741..58-750); Div. 26 O (§58-771..58-780); Div. 27 PD (§58-801..58-810); Div. 28 PS (§58-831..58-842); Div. 29 C/TC (§58-861..58-878); Div. 30 D Downtown (§58-901..58-921); Div. 31 BP (§58-931..58-940). Article III overlays: Div. 4 AOD (§58-1071..58-1078); Div. 7 RVSOD (§58-1162+).
- Naples' coastal residential height definition (c§58-148, c§58-178, c§58-208, c§58-238) measures the 30-ft height from the GREATER of three datums: (a) FBC first-habitable-floor elevation, (b) +18 in. above the FL DEP first-habitable-floor structural-support requirement, or (c) average natural grade. This effectively makes the height limit measure-from-base-flood-elevation in a flood zone, allowing structures to be ~30 ft above design flood elevation rather than 30 ft above natural grade — a coastal-Florida hallmark.
- Naples' R1-15A district uses plat-defined minimum lot area (c§58-114), not a numeric square-foot value. Lots are defined by reference to specific plats (Lantern Lake Section Port Royal, Cutlass Cove Section Port Royal, etc.). Fractional portions of platted lots may be split/combined to create one whole single-family lot.
- R1-10A vs R1-10: variants distinguished by setbacks (R1-10A 10 ft side / 30 or 40 ft front; R1-10 7.5 ft side / 30 ft front) and floor-area minimums (R1-10A 1,400/1,600; R1-10 1,200/1,600). Both are 10,000 sf min lot, 30-ft height. R1-10A applies to specific named-street fronts (e.g. Crayton Rd, Park Shore Dr).
+ 7 more in Quirks & notes
Districts
| Code | Name | Category | Min lot | Height | Coverage | FAR | Du/ac | Parking | Setbacks F/S/R |
|---|---|---|---|---|---|---|---|---|---|
| RE | RE Rural Estates District | res_sf | 98,010 sf[2] | 30 ft[3] | — | — | — | — | 75[1] / — / — |
| R1-E | R1-E Beach Estate District | res_sf | 67,500 sf[5] | 35 ft[6] | — | — | — | — | 50[4] / — / — |
| R1-15A | R1-15A Single-Family Residence District (plat-defined) | res_sf | —[10] | 30 ft[11] | — | — | — | — | 40[7] / 12.5[8] / 30[9] |
| R1-15 | R1-15 Single-Family Residence District (15,000 sf min lot) | res_sf | 15,000 sf[15] | 30 ft[16] | — | — | — | — | 40[12] / 10[13] / 30[14] |
| R1-10 | R1-10 Single-Family Residence District (10,000 sf min lot) | res_sf | 10,000 sf[20] | 30 ft[21] | — | — | — | — | 30[17] / 7.5[18] / 25[19] |
| R1-10A | R1-10A Single-Family Residence District (variant A, 10,000 sf) | res_sf | 10,000 sf[25] | 30 ft[26] | — | — | — | — | 30[22] / 10[23] / 25[24] |
| R1-7.5 | R1-7.5 Single-Family Residence District (7,500 sf min lot) | res_sf | 7,500 sf[30] | 30 ft[31] | — | — | — | — | 25[27] / 7.5[28] / 20[29] |
| R3-6 | R3-6 Multifamily Residence District (6 du/ac) | res_mf | —[33] | —[34] | — | — | 6[35] | — | —[32] / — / — |
| R3-12 | R3-12 Multifamily Residence District (12 du/ac) | res_mf | —[37] | —[38] | — | — | 12[39] | — | —[36] / — / — |
| R3-15 | R3-15 Multifamily Residence District (15 du/ac) | res_mf | — | — | — | — | 15[40] | — | — / — / — |
| R3-18 | R3-18 Multifamily Residence District (18 du/ac) | res_mf | — | — | — | — | 18[41] | — | — / — / — |
| C1 | C1 Retail Shopping District | com | —[42] | —[43] | — | — | — | — | — / — / — |
| C2 | C2 General Commercial District | com | —[44] | —[45] | — | — | — | — | — / — / — |
| C3 | C3 Heavy Commercial District | com | —[46] | —[47] | — | — | — | — | — / — / — |
| D | D Downtown District | cbd | — | 42 ft[48] | — | — | 12 | — | — / — / — |
Confidence: confirmed partial under review not found
Overlays
Parcels within the airport hazard area of Naples Municipal Airport (KAPF), as mapped per the most recent FAA Part 150 Study; four noise impact zones of differing intensities established under c§58-1077.
| purpose | Per c§58-1071: 'Provide for adoption, administration and enforcement of airspace protection and land use compatibility measures for the airport hazard area of the City of Naples Municipal Airport or portions thereof.' Promotes public safety, protects airport public investment, and prevents creation of hazards to aviation. |
|---|---|
| airspace_height_limits | FAA Part 77 imaginary surfaces (horizontal, conical, approach, transition) codified as height restrictions within the AOD per c§58-1072..58-1076. Structures penetrating Part 77 surfaces require FAA review (Form 7460-1). |
| noise_impact_zones | Four noise zones of differing intensities established per c§58-1077 keyed to the most recent FAA Part 150 Study (latest update approved per Federal Register 2024-12-19). Land-use standards per c§58-1078 establish permitted/prohibited land uses per zone, an appeals process, soundproofing requirements, and notification procedures. |
| soundproofing_standard | Per c§58-1077: aircraft sound isolation performance standards must be certified by a registered professional architect or engineer. |
| federal_link | Implements FAA Part 77 airspace surfaces (c§14 CFR 77) and FAA Part 150 noise compatibility program at the local zoning level; KAPF is civil general-aviation, NOT military, so AICUZ is inapplicable. |
Parcels mapped into the RVSOD per c§58-1162 ('District applicability'). Per c§58-1162 verbatim snippet: 'The regulations in this division [Division 7, Recreational Vehicle Storage Overlay District (RVSOD)] are applied as an overlay district on a neighborhood-by-neighborhood basis, with areas designated on the zoning map as RVSOD (for example, R1-10, RVSOD).'
| purpose | Enables regulated RV-storage uses (principal or accessory) on mapped parcels where the underlying zoning would not otherwise permit them, with design/screening/operational standards. Typical of Gulf-coast retiree-market cities. |
|---|---|
| geographic_trigger | Parcels within the RVSOD boundary per c§58-1162 — narrow, neighborhood-by-neighborhood; not citywide. Mapped on the official zoning map (e.g. 'R1-10, RVSOD'). |
| stacking_with_base | Overlay layers RV-storage as an allowed use on top of base-district controls (e.g. R1-10 + RVSOD); base dimensional standards generally apply. |
| v1_artifact_rejected | The legacy v1 overlay parameter 'height multiplier: -0.05' is a v1 synthesizer artifact, not a primary-source rule, and remains discarded. |
Parcels mapped D Downtown on the official zoning map — covers the 5th Avenue South / downtown Naples commercial core and related mixed-use blocks.
| purpose | Governs the Naples downtown commercial core as a base district with enhanced design/form standards. Functions as a hybrid between a base commercial district and a downtown/CBD overlay; Division 30 houses dimensional and use tables. |
|---|---|
| max_height_ft | Per c§58-910: 'Throughout the downtown district, the maximum height for any building, including residential, shall be limited to 3 stories and 42 feet, measured from the 1st-floor FEMA elevation to the peak of the roof or the highest point of any appurtenance.' |
| residential_density_cap_5th_ave_s_area | Residential density within the area bounded by 5th Ave S, 8th Street, 7th Ave N, and Goodlette-Frank Rd is capped at 12 units/acre overall (Naples Planning Department public materials, Comp Plan policy). |
| 5th_ave_south_special_treatment | 5th Avenue South commercial corridor has distinctive form/character standards layered via Ch. 56 Supplemental Standards and Article III specials; transient lodging provisions referenced in city Planning Dept files. |
| dimensional_detail_under_review | FAR, setback, and lot coverage specifics for D Downtown require c§58-901..58-921 full retrieval (Municode SPA blocker). Height and 5th Ave S density cap confirmed. |
Parcels within FEMA-mapped Special Flood Hazard Areas (SFHA) — Zones VE, AE, AH, AO covering most of west and south Naples. Collier County FIRM panels are the controlling map.
| regulatory_basis | FEMA NFIP compliance via the City's floodplain ordinance (Ch. 26 'Floods') and building-code flood provisions (FBC-R, ASCE 24). |
|---|---|
| freeboard | Per City of Naples Building Department public information: 'In City of Naples, Building Code requires the Finish Floor Elevation to be at least one foot higher than the stated Base Flood Elevation.' Standard: BFE + 1 ft minimum. |
| freeboard_example | Per City Building Dept: if BFE = 7 ft, lowest floor must be ≥ 8 ft. |
| cccl_interaction | West-side (Gulf-front) parcels are simultaneously subject to FDEP CCCL permitting under FL Statute Ch. 161 (see state preemptions). FDEP Rule 62B-33 and CCCL siting may be more restrictive than NFIP minimums. |
| wind_borne_debris_region | Per ASCE 7, Naples / Collier County is in the Wind-Borne Debris Region with 160-170 mph ultimate design wind speed; impact-rated glazing or shutters required by FBC. |
| federal_link | FEMA NFIP + FBC implementation. |
Parcels within the Category 1 SLOSH zone per Collier County / FL DEO mapping — includes the entire west-Naples beach/Gulf-front fabric (Port Royal, Aqualane Shores, Olde Naples, Moorings, Park Shore, areas west of US-41).
| regulatory_basis | FL Statute c§163.3178(9) requires comp-plan amendments increasing density in CHHA to demonstrate maintained hurricane-evacuation clearance times or provide mitigation. |
|---|---|
| geographic_trigger | Category 1 SLOSH polygon (most stringent surge zone) per FL DEO / Collier County GIS. |
| interaction_with_lla | LLA density floor on CHHA-located qualifying parcels remains subject to comp-plan consistency test — a comprehensive-plan amendment would still be required for density increases beyond comp-plan caps. |
| interaction_with_cccl | CCCL is the coastal-construction overlay; CHHA is the broader surge zone. A given parcel may be in both. |
Parcels abutting Naples Bay, Moorings Bay, Doctors Bay, Gordon River, and Gulf-front mangrove fringes; conservation/preservation-designated parcels citywide.
| in_district_pattern | c§58-122 confirmed: seawall/boat-slip/revetment standards are in-district within R1-15A rather than a separate citywide environmental overlay. Side yard setback for piers, floating piers, pilings, vessels moored to piers, boat lifts, and vessels supported on boat lifts (constructed on or after 1999-09-15) is 20 ft from side property lines and riparian lines; boat slips cannot encroach into the 20-ft side yard setback. |
|---|---|
| no_separate_overlay_division | No standalone Article III environmental overlay division surfaced; environmental standards are in-district + via FDEP/FWC permitting. |
| federal_link | Clean Water Act c§404 (USACE permitting for fill in waters/wetlands); FWC manatee protection zones in surrounding waters. |
5th Avenue South commercial corridor (downtown Naples) — parcels abutting or fronting 5th Ave S within the D Downtown context.
| purpose | Special form/character and transient-lodging standards for the 5th Avenue South corridor, Naples' principal downtown retail/restaurant/hotel street. |
|---|---|
| stacking_with_d_downtown | Layers form/character and transient-lodging standards on top of D Downtown base. The D Downtown 3-story / 42-ft cap (c§58-910) applies regardless. |
| content_under_review | Exact overlay section, design standards, height/setback adjustments not retrieved this pass. V1 synthesizer-fabricated 'height multiplier -0.05, setback addition 5 ft' parameters have been discarded. |
| v1_artifact_rejected | V1 token '[SIAS' was orchestrator-flagged as junk; legitimate 5th Ave S regime is real but exact section not retrieved. |
not_applicable — no city-wide HP zoning overlay found in Ch. 58 Art. III index.
| search_performed | Searched elaws.us and municode.com Article III division list for 'historic preservation' overlays. No standalone HP division surfaced. Some individual properties (e.g. Palm Cottage, Naples Pier context) are listed on the National Register of Historic Places, but Naples does not appear to have a city-wide Ch. 58 HP overlay comparable to St. Augustine or Key West. |
|---|---|
| reason | Naples historic preservation is predominantly handled via state/federal register listings and Collier County historic programs rather than a formal Ch. 58 HP zoning overlay division. |
not_applicable
| search_performed | Searched Ch. 58 Art. III division list for TOD / corridor / affordable-housing-bonus overlays. Naples is a ~20k-population coastal city without fixed-rail transit; TOD overlays are not typical. Affordable housing in Naples is primarily driven by state Live Local Act preemption rather than a local bonus overlay. |
|---|---|
| reason | Naples does not have fixed-rail transit (no Brightline/Tri-Rail/Metrorail station); no TOD overlay expected. No local affordable-housing density bonus overlay surfaced — LLA (state) is the operative mechanism. |
State preemptions
Adopted building codes
Statewide — FL Building Code 7th ed
Click a code label to open its state-by-state adoption atlas.
Amendment history
| Date | Kind | Citation |
|---|---|---|
| 2026-04-24 | retrieved at solid promotion | naples-fl.elaws.us per-section Google-snippet retrievals 2026-04-24 (Municode SPA + elaws.us 503 bypass via search-index) |
| 2026-04-19 | retrieved at v2 initial | library.municode.com + naples-fl.elaws.us retrieval attempts 2026-04-19 |
Quirks & notes
- Naples' coastal residential height definition (c§58-148, c§58-178, c§58-208, c§58-238) measures the 30-ft height from the GREATER of three datums: (a) FBC first-habitable-floor elevation, (b) +18 in. above the FL DEP first-habitable-floor structural-support requirement, or (c) average natural grade. This effectively makes the height limit measure-from-base-flood-elevation in a flood zone, allowing structures to be ~30 ft above design flood elevation rather than 30 ft above natural grade — a coastal-Florida hallmark.
- Naples' R1-15A district uses plat-defined minimum lot area (c§58-114), not a numeric square-foot value. Lots are defined by reference to specific plats (Lantern Lake Section Port Royal, Cutlass Cove Section Port Royal, etc.). Fractional portions of platted lots may be split/combined to create one whole single-family lot.
- R1-10A vs R1-10: variants distinguished by setbacks (R1-10A 10 ft side / 30 or 40 ft front; R1-10 7.5 ft side / 30 ft front) and floor-area minimums (R1-10A 1,400/1,600; R1-10 1,200/1,600). Both are 10,000 sf min lot, 30-ft height. R1-10A applies to specific named-street fronts (e.g. Crayton Rd, Park Shore Dr).
- Naples Ch. 58 uses a 'Maximum Building Area' tiered scale per district (c§58-60 RE, c§58-90 R1-E, c§58-120 R1-15A, c§58-150 R1-15, c§58-180 R1-10, c§58-210 R1-10A, c§58-240 R1-7.5) that functions as a hybrid lot-coverage + gross-building-area cap. Per c§58-240 verbatim: 'Building area is defined as that portion of lot coverage which is the sum total of all lot area covered by roof and which is enclosed by walls or another enclosure system. Mesh screening shall not be considered a wall or enclosure system.'
- Naples Municipal Airport (KAPF) is civil general-aviation (not military); the Airport Overlay District (AOD) per c§58-1071..58-1078 implements FAA Part 77 airspace and Part 150 noise compatibility at the local level but is NOT an AICUZ overlay. Federal_overlay_refs lists FAA_Part_77 and FAA_Part_150 — not AICUZ. Most recent FAA Part 150 update approved per Federal Register 2024-12-19.
- Coastal exposure is dominant: west and southwest Naples are simultaneously subject to FDEP CCCL (seaward of the control line), CHHA (Category 1 SLOSH), and FEMA NFIP SFHA (VE/AE zones). Three-layer state/federal/local regulation on Gulf-front parcels is a defining characteristic. City freeboard is BFE + 1 ft (Building Department public information).
- Live Local Act density floor in Naples: jurisdiction-wide residential density ceiling is R3-18 at 18 du/ac (c§58-451), which establishes the LLA density floor on qualifying commercial/industrial/MU parcels. This is HIGHER than the 12 du/ac overall cap in the 5th Ave S / 8th St / 7th Ave N / Goodlette-Frank Rd downtown context area.
- V1 record contained fabricated district entries labeled 'Minimum Lot Area', 'Maximum Height', 'Lot Coverage', 'FAR', 'Density (DU/AC)', 'Parking Ratio', 'Minimum Front Setback', 'Minimum Side Setback', 'Minimum Rear Setback', 'Minimum Yards', 'Other Parameters', 'Parameter', 'Setbacks' — these are column headers / parameter names, NOT districts. All discarded in this v2 regeneration. The v1 pattern of stamping every 'district' with identical 5000/35/0.5/0.5/null/2/25/25/10 values is pure synthesizer output and not primary-source.
- V1 overlay list contained a garbled token '[SIAS' labeled as '5th Avenue South Special'; this is a parser artifact. A legitimate 5th Ave S special-treatment regime exists but the exact section was not retrieved this pass; captured under '5AS — under_review' overlay entry.
- V1 overlay parameters 'height multiplier: -0.05' and 'setback addition (ft): 5' on RVSOD, D Downtown, and the garbled 5th Ave S entries are pure synthesizer artifacts — these specific multipliers/additions are not in primary Ch. 58 source. Discarded in this v2 regeneration.
Formulas
Definitions
- height
- Building height per Ch. 58 district-specific 'Maximum height' sections — in coastal residential districts, measured from the greater of: (1) the lowest floor elevation as required by the Florida Building Code for the first habitable floor, (2) eighteen inches above the FL DEP requirement for the first habitable floor structural support, or (3) the average natural grade. Citation pattern: c§58-148 (R1-15), c§58-178 (R1-10), c§58-208 (R1-10A), c§58-238 (R1-7.5).
- lot_coverage
- Building footprint / lot area per Ch. 58 district-specific 'Maximum building area' standards (e.g. c§58-180 R1-10, c§58-210 R1-10A, c§58-240 R1-7.5).
- building_area_definition
- Per c§58-240: 'Building area is defined as that portion of lot coverage which is the sum total of all lot area covered by roof and which is enclosed by walls or another enclosure system. Mesh screening shall not be considered a wall or enclosure system. Building area is calculated as the area within the outermost perimeter of the enclosing walls or enclosure system.'
- far
- Naples primarily regulates residential building bulk via 'Maximum building area' (a tiered lot-coverage scale) per c§58-180/c§58-210/c§58-240 rather than a numeric FAR. D Downtown and commercial districts may use FAR-style controls per c§58-901..c§58-921.
- du_ac
- Dwelling units per gross acre. R3-x district code suffix encodes the cap: R3-6 = 6 du/ac (c§58-271), R3-12 = 12 du/ac (Div. 10), R3-15 = 15 du/ac (Div. 12/13/14), R3-18 = 18 du/ac (Div. 15). Within the area bounded by 5th Ave S, 8th St, 7th Ave N, and Goodlette-Frank Rd, residential density is overall-capped at 12 du/ac per Naples Planning Department public materials and Comp Plan policy.
- setback_front
- Front yard setback per district-specific 'Minimum yards' section (e.g. c§58-146 R1-15, c§58-176 R1-10, c§58-206 R1-10A, c§58-236 R1-7.5).
- setback_side
- Side yard setback per district-specific 'Minimum yards' section. In coastal residential districts (e.g. R1-7.5, R1-10, R1-10A, R1-15), the side-yard setback applies to the first 15 feet of vertical height; additional height must remain within a 12:12 slope beyond the initial setback (a daylight-plane rule).
- setback_rear
- Rear yard setback per district-specific 'Minimum yards' section. Rear yards abutting a public alley may be reduced to 15 ft for garages/carports with direct alley access or utility sheds ≤100 sf.
- parking
- Parking ratios governed by Ch. 58 parking standards (per-district 'Minimum off-street parking' sections, e.g. c§58-89 R1-E).
Capacity calculations
- max_footprint_sf
lot_area_sf * lot_coverage (where 'maximum building area' is encoded as percent or tiered scale)- max_gfa_sf
lot_area_sf * far (where FAR applies in commercial / D Downtown) OR maximum_building_area_sf per district-specific Maximum Building Area section in residential- buildable_width_ft
lot_width_ft - setback_side_ft * 2- buildable_depth_ft
lot_depth_ft - setback_front_ft - setback_rear_ft- max_stories_approx
max_height_ft / 10 (D Downtown explicitly capped at 3 stories AND 42 ft per c§58-910)- naples_maximum_building_area_pattern
Naples Ch. 58 uses a 'Maximum Building Area' tiered scale per district (c§58-180 R1-10, c§58-210 R1-10A, c§58-240 R1-7.5, c§58-150 R1-15, c§58-120 R1-15A, c§58-90 R1-E, c§58-60 RE) that functions as a hybrid lot-coverage + gross-building-area cap. The R1-E and RE tiered scale starts at 48% for the first 5,000 sf and steps down for larger lots.
Massing explorer
Interactive 3D comparison across every district. Drag to orbit, scroll to zoom, use the slider to walk districts, and toggle applicable overlays in the right-side panel.
| District | Category | Height | FAR | Coverage | Setbacks | Parking | Density | Min lot | Overlays |
|---|
Sources & references
library.municode.com renders SPA shell to scripted WebFetch (Wave-pattern Municode platform 403/SPA block). Direct curl with Mozilla UA to naples-fl.elaws.us (the City's eLaws code-mirror at the naples-fl subdomain) returned 503 throughout 2026-04-24. Bypass used: Google search-index snippets of naples-fl.elaws.us section pages (snippet returns include section titles, headers, and quoted body text directly from the page). Each district's dimensional values were obtained via per-section Google snippet retrieval (search 'naples-fl.elaws.us "58-XXX"'); cross-corroborated against the Naples Code's structural index. All section anchors below carry p§-form citation to the c§ Naples Code section number (e.g. c§58-236) consistent with the elaws.us URL scheme http://naples-fl.elaws.us/code/coor_ch58_artii_div<N>_sec58-<NNN>. Naples Municipal Airport (KAPF) AOD parameters supplemented by flynaples.com/airport-zoning (city-airport-authority publication, not aggregator). Floodplain freeboard +1 ft confirmed via City Building Department public information (naplesgov.com/building search-snippet, City Public-information disclosure: 'In City of Naples, Building Code requires the Finish Floor Elevation to be at least one foot higher than the stated Base Flood Elevation').
- http://naples-fl.elaws.us/code/coor_ch58
- https://www.naplesgov.com/planning
- https://www.naplesgov.com/building/page/flood-zone-maps
- https://www.naplesgov.com/building/page/building-or-modifying-concerns
- https://www.flynaples.com/airport-zoning/
- https://www.flynaples.com/special-district-information-2/
- https://flynaples.com/wp-content/uploads/2021/05/Appendix-E-Land-Use-min.pdf
- https://flynaples.com/wp-content/uploads/Appendix-J-Official-Noise-Exposure-Maps-1.pdf
- [1] §58-56
- [2] §58-54
- [3] §58-58
- [4] §58-86
- [5] §58-84
- [6] §58-88
- [7] §58-116
- [8] §58-116
- [9] §58-116
- [10] §58-114
- [11] §58-118
- [12] §58-146
- [13] §58-146
- [14] §58-146
- [15] §58-144
- [16] §58-148
- [17] §58-176
- [18] §58-176
- [19] §58-176
- [20] §58-174
- [21] §58-178
- [22] §58-206
- [23] §58-206
- [24] §58-206
- [25] §58-204
- [26] §58-208
- [27] §58-236
- [28] §58-236
- [29] §58-236
- [30] §58-234
- [31] §58-238
- [32] §58-266
- [33] §58-264
- [34] §58-268
- [35] §58-271
- [36] §58-296
- [37] §58-294
- [38] §58-298
- [39] §58-301
- [40] §58-361
- [41] §58-451
- [42] §58-534
- [43] §58-538
- [44] §58-594
- [45] §58-598
- [46] §58-654
- [47] §58-658
- [48] §58-910
Research status
Publication gates
| primary url present | passed | |
|---|---|---|
| no aggregator cited | passed | |
| confidence tags full form | passed | |
| overlays have parameters trigger confidence | passed | |
| preempt section city specific | passed |
Data quality
- Municode SPA blocker persists for full body retrieval of Article II dimensional tables; values populated from elaws.us section-anchor snippets cross-corroborated against the Naples Code structural index. Per-section Municode body extraction would allow 'p§' → 'c§' upgrade for ~24 partial fields.
- R3-6 / R3-12 / R3-15 / R3-18 specific dimensional standards (min lot, yards, max height, max building area) require c§58-264..58-271 (R3-6), c§58-294..58-301 (R3-12), c§58-354..58-361 (R3-15 standard), c§58-384..58-392 (R3-15 Coquina Sands), c§58-414..58-422 (R3-15 Moorings), c§58-444..58-451 (R3-18) full retrieval.
- C1 / C1-A / C2 / C2-A / C3 / C4 / HC dimensional tables (min lot, yards, max height, max building area, parking) require Div. 17/18/19/20/21/22/23 full retrieval; section anchors confirmed.
- I (Industrial), M (Medical), O (Office), PD (Planned Development), PS (Public Service), C/TC (Conservation), BP (Business Park) dimensional tables require Div. 24/25/26/27/28/29/31 full retrieval.
- D Downtown FAR / setback / lot-coverage detail for c§58-901..58-921 not retrieved (height confirmed at 3 stories / 42 ft via c§58-910).
- AOD Part 77 surface tables c§58-1072..58-1076 and per-zone permitted-use matrix c§58-1078 require browser-rendered Municode for full table extraction.
- RVSOD full standards c§58-1163+ (screening, design, operational) require Municode body retrieval.
- 5th Avenue South Special Area / Overlay exact section anchor in Ch. 58 Art. III not surfaced; legitimately exists per Naples Planning materials but not retrievable this pass.
- Code supplement effective date and version number not retrieved (Municode supplement metadata not extractable from SPA shell); code_version recorded as 'mid-2025 supplement (Municode "latest" alias)'.
- Ch. 26 Floods full ordinance text not retrieved; freeboard +1 ft confirmed via Naples Building Dept public information snippet.
Known issues
Other cities in this state
Nearest-alphabetical profiles. Click through to compare zoning patterns side-by-side.